Anritsu 683XXB User Manual

Page of 514
1-7
OPTIONS
The following instrument options are available.
q
Option 1, Rack Mounting. Rack mount kit containing a set of
track slides (90
° tilt capability), mounting ears, and front panel
handles for mounting the instrument in a standard 19-inch
equipment rack.
q
Option 2A, 110 dB Step Attenuator. Adds a 10 dB per step
attenuator with a 110 dB range for models having a high-end
frequency of
£26.5 GHz. Output power is selected directly in dBm
on the front panel (or via GPIB). Rated output power is reduced.
q
Option 2B, 110 dB Step Attenuator. Adds a 10 dB per step
attenuator with a 110 dB range for models having a high-end
frequency of
£40 GHz. Output power is selected directly in dBm
on the front panel (or via GPIB). Rated output power is reduced.
q
Option 2C, 90 dB Step Attenuator. Adds a 10 dB per step
attenuator with a 90 dB range for models having a high-end
frequency of
£50 GHz. Output power is selected directly in dBm
on the front panel (or via GPIB). Rated output power is reduced.
q
Option 2D, 90 dB Step Attenuator. Adds a 10 dB per step
attenuator with a 90 dB range for models having a high-end
frequency of
£60 GHz. Output power is selected directly in dBm
on the front panel (or via GPIB). Rated output power is reduced.
q
Option 6, Phase Modulation (
FM). Adds phase modulation ca-
pability. The internal FM generator becomes the FM/
FM genera-
tor. (Not available in combination with Option 7.)
q
Option 7, Delete AM/FM Generator. Deletes the internal AM
and FM generators. External AM and FM capability remains un-
changed. (Not available in combination with Option 8 or Option
20.)
q
Option 8, Internal Power Meter. Adds an internal power
meter that is compatible with
ANRITSU
560-7, 5400-71, or 6400-
71 series detectors. (Not available in combination with Option 7.)
q
Option 9, Rear Panel RF Output. Moves the RF output con-
nector to the rear panel.
q
Option 11, 0.1 Hz Frequency Resolution. Provides frequency
resolution of 0.1 Hz.
q
Option 14,
ANRITSU
360B VNA Compatibility. Modifies rack
mounting hardware to mate unit in a
ANRITSU
360B VNA con-
sole.
q
Option 15B, High Power Output. Adds high-power RF compo-
nents to the instrument providing increased RF output power in
the 2–26.5 GHz frequency range. Option 15B is standard in mod-
els having a high-end frequency that is >40 GHz.
q
Option 16, High-Stability Time Base. Adds an ovenized,
10 MHz crystal oscillator with <5 x 10
–10
/day frequency stability.
682XXB/683XXB MM
1-7
GENERAL
OPTIONS
INFORMATION