Tektronix AFG3000 User Manual

Page of 230
Syntax and Commands
3-68
AFG3000 Series Arbitrary/Function Generators Reference Manual
[SOURce[1|2]]:PULSe:DELay
This command sets or queries the lead delay of the pulse waveform for the speci-
fied channel. 
Group
Source
Syntax
[SOURce[1|2]]:PULSe:DELay {<delay>|MINimum|MAXimum}
[SOURce[1|2]]:PULSe:DELay?{MINimum|MAXimum}
Arguments
<delay>::=<NR2>[<units>] 
where <NR2> is the lead delay.
 <units>::=[ns | 
µs | ms | s]
Setting range: 0 ns to Pulse Period – {Pulse Width + 0.8 × (Leading Edge Time + 
Trailing Edge Time)}
Returns
<delay>
Examples
SOURce1:PULSe:DELay 20ms
sets the CH 1 lead delay to 20 ms.
[SOURce[1|2]]:PULSe:HOLD
The [SOURce[1|2]]:PULSe:HOLD command sets the arbitrary/function generator 
to hold either pulse width or pulse duty.
The [SOURce[1|2]]:PULSe:HOLD? command returns WIDTh or DUTY.
Group
Source
Syntax
[SOURce[1|2]]:PULSe:HOLD {WIDTh|DUTY}
[SOURce[1|2]]:PULSe:HOLD?
Arguments
WIDTh means that the arbitrary/function generator holds the pulse width setting.
DUTY means that the arbitrary/function generator holds the pulse duty setting.
Returns
WIDT|DUTY
Examples
SOURce1:PULSe:HOLD WIDTh
holds the CH 1 pulse width setting.