Sine/Square Menu
Table 2-1 shows the Sine and Square menu.
Table 2-1: Sine/Square Menu
First Level
Second Level
Third Level
Description
Frequency/Period/
Phase Menu
Frequency
Selects Frequency as a 
parameter to be changed.
Period
Selects Period as a parameter 
to be changed.
Frequency (Period)
1
CH1=CH2
Off  On
1.   Dual-channel model only.
Toggles between Off and On to 
disable/enable the function that 
sets the CH1 and CH2 to the 
same value.
Phase
Selects Phase as a parameter to 
be changed.
Align Phase
Use to align the phase of two 
channel signals.
Amplitude/Level Menu
Amplitude
Selects Amplitude as a 
parameter to be changed.
Offset
Selects Offset as a parameter to 
be changed.
High Level
Selects High Level as a 
parameter to be changed.
Low Level
Selects Low Level as a 
parameter to be changed.
-more- (1 of 2)
Units [Vpp]
Vpp
Vrms
dBm
2
2.   dBm is used only for sine waveform.
Option buttons
Level
CH1=CH2
Off  On
Toggles between Off and On to 
disable/enable the function that 
sets the CH1 and CH2 to the 
same value.
-more- (2 of 2)
Run Mode Menu
Continuous
–––
Modulation
Sweep
Burst
Output Menu