Tektronix AFG3000 User Manual
Syntax and Commands
3-78
AFG3000 Series Arbitrary/Function Generators Reference Manual
[SOURce[1|2]]:SWEep:MODE
The [SOURce[1|2]]:SWEep:MODE command selects auto or manual for the sweep
mode for the specified channel.
mode for the specified channel.
The query command returns the sweep mode for the specified channel.
Group
Source
Related Commands
[SOURce[1|2]]:SWEep:HTIMe
[SOURce[1|2]]:SWEep:RTIMe
[SOURce[1|2]]:SWEep:TIME
TRIGger[:SEQuence]:SOURce
TRIGger[:SEQuence]:TIMer
[SOURce[1|2]]:SWEep:RTIMe
[SOURce[1|2]]:SWEep:TIME
TRIGger[:SEQuence]:SOURce
TRIGger[:SEQuence]:TIMer
Syntax
[SOURce[1|2]]:SWEep:MODE {AUTO|MANual}
[SOURce[1|2]]:SWEep:MODE?
Arguments
AUTO sets the sweep mode to auto. The instrument outputs a continuous sweep at
a rate specified by Sweep Time, Hold Time, and Return Time.
a rate specified by Sweep Time, Hold Time, and Return Time.
MANual sets the sweep mode to manual. The instrument outputs one sweep when
a trigger input is received.
a trigger input is received.
Returns
AUTO|MAN
Examples
SOURce1:SWEep:MODE AUTO
sets the CH1 sweep mode to auto. The instrument outputs a continuous sweep.
sets the CH1 sweep mode to auto. The instrument outputs a continuous sweep.