Bosch 2.4 User Manual

Page of 15
DCN Next Generation 2.40 Release Notes 
en | 12 
 
Bosch Communications Systems | 2007 March 
9  Release 1.10 
9.1  General 
9.1.1  Release Date 
June 25
th
 2004 
9.1.2  Firmware/FPGA versions 
 
Product 
FPGA SWA 
SWB 
LBB 4100 
1.00 
1.10.0569 
2.11.1416 
LBB 4112 
-- 
1.3 
-- 
LBB 4120 
1.1 
1.00.0569 
-- 
LBB 4124 
1.0 
-- 
-- 
LBB 4402 
-- 
1.10.0569 
2.11.1416 
9.1.3  Compatibility restrictions 
 
LBB 4120 
1.0 
-- -- 
9.2  Errata 
9.2.1  Audio Expander: not possible to disable 
audio outputs using input contacts 
In paragraph 10.3.5 of the Installation and User 
Instructions is described that the audio outputs 1 to 
4 can be disabled by closing respectively control 
input 5 to 8. This function is not supported. However 
disabling audio inputs 1 to 4 by closing respectively 
control input 1 to 4 is supported. 
9.2.2  Audio Expander: power consumption 7.6 
Watt 
The power consumption of the LBB 4402/00 Audio 
Expander is 7.6 Watt instead of 5.6 Watt. Add 
power by using a Network Splitter (LBB 4410/00) 
with an external power supply in case the power is 
insufficient. 
9.3  Known limitations 
9.3.1  System: reset of units after connecting 
new units to a trunk 
When a Channel Selector, Interpreter desk, Trunk 
Splitter, Tap-off unit or Extended power supply is 
connected to a trunk, which is connected to the LBB 
4100 Central Control Unit, it can happen that all 
units in that same trunk reset. After reset the units 
come back to default settings. The units in the trunk 
will not reset if a unit is connected to a Tap-off outlet 
of a Tap-off unit. 
 
If it is important that the channel selectors are not 
reset to default in above described situation: use 
the auto restore function of the channel selector. 
See the Installation and User Instruction for how to 
set the auto restore function. 
 
If it is important that you can connect and replace 
each unit during operation, without the above 
described reset behavior: power the units with the 
LBB 4106 Extension Power Supply Unit. The LBB 
4106 Extension Power Supply Unit is less prone to 
the inrush current. 
9.3.2  System: noise during system start 
During system start up noise is heard for a 
maximum time of 30 seconds. The noise is heard 
from the headphones connected to the channel 
selectors and interpreter desks and the loudspeaker 
of the interpreter desks. 
9.3.3  Central Control Unit: fault contact closed 
despite system is ok 
When the system is initialized for four times, the 
fault contact is activated, while the system works 
properly. Switch off the CCU in order to reset the 
fault contact. 
9.3.4  Audio Expander: not more than one 
input used for floor insertion 
Undefined behavior occurs if more than one audio 
input is used for floor insertion per system. Use not 
more than one audio input for floor insertion.