Bosch 2.4 User Manual

Page of 15
DCN Next Generation 2.40 Release Notes 
en | 7 
 
Bosch Communications Systems | 2007 March 
4  Release 2.10 
4.1  General 
4.1.1  Release Date 
November 8th 2005 
4.1.2  Firmware/FPGA versions 
 
Product 
FPGA SW 
FW 
DCN-CCU 1.06 
2.10.1178 
3.40.1785 
DCN-CON 
DCN-CONCS 
1.0 -- 
-- 
DCN-CONFF 
DCN-CONCM 
1.0 1.00.XXXX 
-- 
DCN-DDB --  1.3.XXXX 
-- 
DCN-DDI 1.2 
-- 
-- 
DCN-DIS 1.11 
-- 
-- 
DCN-FCS 1.0 -- 
-- 
DCN-IDESK 1.3  1.20.XXXX 
-- 
LBB 4402/00 
-- 
2.10.1178 
3.40.1785 
PRS-4DEX4 -- 
2.10.1178 
3.40.1785 
LBB 4404/00 
-- 
2.10.1178 
3.40.1785 
4.1.3  Compatibility restrictions 
The following versions are not compatible with this 
release: 
 
Product 
FPGA SW 
FW 
DCN-CCU 
≤1.06 -- 
-- 
LBB 4120 
1.1 
-- -- 
4.2  Errata 
4.2.1  Integrus Manual: standby function 
When switching off the DCN Next Generation CCU, 
the Integrus transmitter indicates “Network Error” 
and not “standby”. However, the radiators do switch 
to the standby mode.  When the DCN Next 
Generation CCU is switched on again, the Integrus 
transmitter and the radiators return to the “on” 
mode. 
4.2.2  Auxiliary function 
The DCN-DISCS does not support “single delegate 
with auxiliary control mode” as mentioned in the 
Installation and User Instruction. 
4.3  Known limitations 
4.3.1  Microphone will be reset to default after 
de-init. 
When a de-init is activated at the CCU the 
microphone is always set to microphone mode 
“open” with 2 active microphones. 
4.3.2  Use of Developers Toolkit 
The developers toolkit provided on this CD-ROM 
can only be used with Windows 2000. 
4.3.3  Text “starting” remains on CCU 
In a system with an Audio Expander and an 
Integrus transmitter, the text “starting” can remain 
on the display of the CCU after start up. On the 
display of the Audio Expanders 'No Network' is 
flashing. 
Switch the network mode of the Integrus transmitter 
to enabled and the problem will be solved. 
4.3.4  Network mode disabled results in faults 
When the network mode of a transmitter is set to 
disabled, while connected to a DCN Next 
Generation system, noise on the loudspeakers in 
the DCN Next Generation system can occur. 
 
Switch the network mode of the Integrus transmitter 
to enabled and the problem will be solved.