Specifications
31
Specifications
EM 100
RF characteristics
Modulation
wideband FM
Receiving frequency ranges
516–558, 566–608, 626–668, 734–776, 
780–822, 823–865 MHz (A to E, G, see page 4)
Receiving frequencies
1,680 frequencies, tuneable in steps of 25 kHz
20 frequency banks, each with up to 12 factory-preset 
channels, intermodulation-free
1 frequency bank with up to 12 user programmable 
channels 
Switching bandwidth
42 MHz
Nominal/peak deviation
±
24 kHz / 
±
48 kHz
Receiver principle
true diversity
Sensitivity (with 
HDX
, peak deviation)
<
 2,5 μV for 52 dBA 
rms S/N 
Adjacent channel rejection
typ. 
 65 dB
Intermodulation attenuation
typ. 
 65 dB
Blocking
 70 dB
Squelch
Off, Low: 5 dB
μ
V, Middle: 15 dB
μ
V, High: 25 dB
μ
V
Pilot tone squelch
can be switched off
Antenna inputs
2 BNC sockets
AF characteristics
Compander system
Sennheiser 
HDX
EQ presets (switchable, 
affect the line and monitor outputs):
Preset 1: “
Flat
Preset 2: “
Low Cut
–3 dB at 180 Hz
Preset 3: “
Low Cut/High Boost
–3 dB at 180 Hz
+6 dB at 10 kHz
Preset 3: “
High Boost
+6 dB at 10 kHz
S/N ratio (1 mV, peak deviation) 
 110 dBA 
THD 
≤ 
0.9% 
AF output voltage
(at peak deviation, 1 kHz AF)
¼’’ (6.3 mm) jack socket (unbalanced): +12 dBu
 
XLR socket (balanced): +18 dBu
Adjustment range of audio output level
48 dB (in steps of 3 dB)
+6 dB gain reserve
Overall device
Temperature range
–10°C to 
+
55°C
Power supply
12 V 
Current consumption
300 mA
Dimensions
approx. 190 x 212 x 43 mm
Weight
approx. 980 g