Product overview
6
Overview of the displays of the EM 100 receiver
After switch-on, the receiver displays the standard display “
Receiver Parameters
”. For further
illustrations and examples of the different standard displays, please refer to 24. This stan-
dard display displays the operating states of the receiver.
Display
Meaning
RF level “
RF
” 
(Radio Frequency)
Audio level “
AF
(Audio Frequency)
Frequency bank and 
channel
Current frequency bank and channel number
Frequency 
Current receiving frequency
Name 
Freely selectable name of the receiver
Pilot tone “
P
” 
Activated pilot tone evaluation
Muting function “
MUTE
Receiver is muted
Receiver does not output an audio signal 
(see also page 28).
Battery status of the 
transmitter
Charge status:
Lock mode icon
Lock mode is activated
543.200
EW100 G3
  1. 1
PEAK
MUTE
P
-10
0
40
25
10 -20
-30
AF
RF
 MHz
40
30
20
10
RF
Diversity display:
 Antenna input I is active
 Antenna input II is active
RF signal level: 
Field strength of the transmitted signal
Squelch threshold level
PEAK
-10
0
-20
-30
-40
AF
Modulation of the transmitter
with peak hold function.
When the level display for audio level shows full
deflection, the audio input level is excessively
high. When the transmitter is overmodulated
frequently or for extended periods of time, the
PEAK
” display is shown inverted.
approx. 100%
approx. 70%
approx. 30%
Icon is flashing; charge status is critical