Sony UWP-X1/X2 User Manual

Page of 48
Operation
34
Operation
The procedure below is the
same for all UWP series
components (UTX-B1/H1 and
URX-P1/R1/M1).
1
Make all necessary connections
on the tuner.
For examples of UWP series
component connections, see
“System Configurations” on page
35.
2
Set the transmission channel on
the transmitter, and then turn off
the unit.
For details on setting the
transmission channel, see “Setting
the transmission channel” on
page 28.
3
Turn on the tuner.
The parameters that were in the
display section when the tuner
was last turned off appear again.
Note
Before turning on the tuner, turn
down the volume of the
equipment connected to the tuner.
Otherwise, noise will be produced
when the tuner is turned on.
4
Set the reception channel on the
tuner.
For details on setting the
reception channel, see “Setting
the reception channel” on page
29.
5
Turn on the transmitter.
If noise is heard
Depending on the environment where
the UWP series components are
installed, external noise or radio
waves may disrupt transmission on
certain channels.
When selecting a channel under these
circumstances, turn off the transmitter.
Then, on the tuner, select a channel for
which the RF indications do not
appear in the display section or for
which the RF indicator does not light
up (i.e., a channel free from noise or
radio wave interference). Set the same
channel on the transmitter.
Note
To prevent interference or noise,
please take the following precautions.
• Do not use two or more transmitters
with the same wireless channels.
• When operating two or more UWP
series simultaneously, set each series
to a different channel within the
same channel group.
• Keep the reception antenna and the
transmitter separated more than 3
meters (9 feet 11 inches).
• When operating two or more UWP
series simultaneously with the same
channel group, make sure that they
are at least 100 meters (330 feet)
apart, but within clear sight of each
other. (The actual distance may
differ depending on the
circumstances.)