Roland ARX-01 User Manual

Page of 148
 
27
 
Volume adjustment 
(Tone/Output screen)
 
fig.signal-flow.eps
 
Here you can make settings related to the output of each tone.
 
Signal Flow
Reverb Send Level
Inst
Pan
Input
Level
COMP/EQ
Tone
Level
Output
Level
Output
Assign
DRY
MFX
to Reverb
to MFX
to Mixer
 
Parameter
Value
Description
 
Pan
L64 –0 –63R
Adjusts the pan of the tone. “L64” 
places the sound at far left, “0” at 
the center, and “63R” at the far 
right.
Tone Level
 0–127
Specifies the volume of the tone. 
You’ll use this parameter mainly to 
adjust the volume balance relative 
to the other tones.
Output Level
0–127
Specifies the signal level of each 
tone.
Output Assign
DRY, MFX
Selects whether each tone will out-
put its original sound or will use 
MFX.
 
DRY
 
: The original sound will be 
output without processing.
 
MFX
 
: The sound will be sent 
through the multi-effect before be-
ing output.
Reverb Send 
Level
0–127
Specifies the level of the signal sent 
from each tone to reverb.
Mute Sw
ON/OFF
Turns muting on/off for each tone.
ARX-01_e.book 27 ページ 2008年2月19日 火曜日 午後4時7分