Roland ARX-01 User Manual

Page of 148
 
66
 
07:STEP FILTER
28:SLICER
The above two types contain a sixteen-step sequencer. 
For these effect types, you can use multi-effect control (
 
 
beginning.
To do this, set the Control Assign setting for that effect type to “Step Reset.”
For example, if you want to use the modulation lever to control Step Reset, 
you would make the following settings.
MFX Control–Source: CC01: MODULATION
MFX Control–Sens:
+63
Control Assign:
Step Reset
With these settings, the step sequence will be reset to the beginning each 
time you operate the modulation lever.
 
About the STEP RESET function
ARX-01_e.book 66 ページ 2008年2月19日 火曜日 午後4時7分