Edirol R-4Pro User Manual

Page of 108
34
Recording
The following describes how to record from a digital device connected to the R-4 Pro digital input 
connector.
fig.digital.eps
● Connections
Connect your digital device to the digital input connector. You will need a separately available XLR type 
cable to connect your device to the R-4 Pro digital input connector.
fig.input-digital.eps
● System settings
1.
Press the R-4 Pro [SYSTEM] button.
2.
1 Recording Setup
, set Input Select to Digital.
3.
Set the sampling frequency to match the input source.
4.
Set the other items in 1 Recording Setup as appropriate 
for the recording you want to make.
* For more about system settings, refer to “System setup” (p. 64).
* The R-4 Pro is able to synchronize to the clock signal of the digital input connector. 
* When the input sampling frequency and set sample size differ, the sampling frequency display blinks and Mute data 
is generated.
● Record button [REC]
Press the [REC] button to begin recording.
For details on recording standby, refer to “Recording standby” (p. 32).
● Other settings
If you want to monitor the sound being recorded, connect headphones to the PHONES jack and use the 
monitor level knob to adjust the volume.
Adjusting the monitor level knob does not affect the level of the sound actually being recorded.
* When recording digital input, you can not use the input level knob to adjust the input level. The limiter and input 
level knobs [SENS] settings are also invalid.
To play back the recorded sound, refer to “Playing back” (p. 37).
Recording digital audio from a digital device
CD player for playback
DIGITAL OUT
DIGITAL IN
R-4_e_new.book  34 ページ  2006年11月20日 月曜日 午後1時9分