Edirol UA-1000 User Manual

Page of 56
 
39
Various settings
 
Reading and writing memories
 
Five sets of UA-1000 settings can be stored within the UA-1000 itself. These stored memories can be read and 
written from UA-1000 Control Panel.
For the procedure, refer to README_E.HTM on the included CD-ROM.
 
Convenient ways to use the OUTPUT PATCH BAY
 
You can store two different settings for the OUTPUT PATCH BAY, and switch between these two settings.
 
DIRECT MONITOR: ON
 
fig.monitor-on
 
If even one 
 
INPUT MONITOR (DIRECT MONITOR)
 
 switch is 
 
ON
 
the 
 
DIRECT MONITOR: ON
 
 settings of the 
 
OUTPUT PATCH BAY
 
 
will be used.
 
* These settings will always be used if the 
 
Direct Monitor Soft Control switch
 
 
of the UA-1000’s front panel is 
 
turned off
 
.
 
DIRECT MONITOR: OFF
 
fig.monitor-off
 
If all of the 
 
INPUT MONITOR (DIRECT MONITOR)
 
 switches are 
 
OFF
 
, the 
 
DIRECT MONITOR: OFF
 
 settings of the 
 
OUTPUT PATCH 
BAY
 
 will be used.
Examples of use
Simply by switching INPUT MONITOR (DIRECT MONITOR) on/off, you can switch between settings for 
monitoring and settings for mastering.
fig.output-monitor
Settings for monitoring
These settings are appropriate when you 
want to hear the sounds being input to the 
UA-1000 from the input jacks.
fig.output-monitor2
Settings for mastering
These settings are appropriate when you 
have finished acquiring audio from the 
input jacks, and are mastering the data on 
your computer.
UA-1000_e.book 39 ページ 2003年8月6日 水曜日 午前11時52分