Casio AP-200 User Manual
![Casio](https://files.manualsbrain.com/attachments/76bb10c5ed22dc25bda27ce93ac32ebe64efb4fa/common/fit/150/50/0de27031ecb5bbe57508fbe18af1d7fa9c82f769f0afcb4f5472bbed175d/brand_logo.png)
15
Send
This message is sent at initialization, when the panel tone selection is changed, and when a chorus on/off operation is
performed.
performed.
Receive
Changes Chorus Send.
9.16
NRPN (62H, 63H)
Format
Send
This message is not sent by this Instrument.
Receive
This Instrument does not have a corresponding NRPN message.
9.17
RPN (64H, 65H)
Format
9.17.1
Pitch Bend Sensitivity
Format
Send
This message is not sent by this Instrument.
Receive
Receipt changes Pitch Bend Sensitivity.
Message Format: BnH 62H vvH (LSB)
BnH 63H vvH (MSB)
n: MIDI Channel Number
vv: Value
Message Format: BnH 64H vvH (LSB)
BnH 65H vvH (MSB)
n: MIDI Channel Number
vv: Value
Message Format: BnH 64H 00H 65H 00H 06H mmH 26H **H
n: MIDI Channel Number
mm:
**:
**:
Value 0 - 24
Ignored
Ignored