Graco 312775G User Manual

Page of 42
Electrical
312775G
21
Electrical
Requirements
NOTE: All options ordered on the ProMix system are 
electrically tested at the factory.
The ProMix operates with 85-250 VAC, 50/60 Hz input 
power, with a maximum of 2 amp current draw. The 
power supply circuit must be protected with a 15 amp 
maximum circuit breaker.
Not included with system:
Power supply cord compatible to your local power 
configuration. Wire gauge size must be 8-14 AWG.
The input power access port 
 
is 22.4 mm 
(0.88 in.) diameter. It accepts a bulkhead strain 
relief fitting or conduit. See F
Connect Main Power
1. Provide power to the EasyKey. Install a bulkhead 
strain relief or conduit bulkhead through the 
EasyKey port 
. See F
2. See F
IG
on page 30 for the L1, N, and ground wiring connec-
tions inside the EasyKey.
3. Ground the EasyKey to a true earth ground. See 
All electrical wiring must be completed by a qualified 
electrician and comply with all local codes and regula-
tions.
Enclose all cables routed in the spray booth and high 
traffic areas in conduit to prevent damage from paint, 
solvent, and traffic.
F
IG
. 12. Main Power Connection
TI12578b
Input Power
Terminal Block
F
IG
. 13. EasyKey Connections and AC Power Switch
AC Power Switch
Graco Web 
Interface
Audible Alarm
Fiber Optic Strain 
Relief Port
I/S Power
Discrete I/O Cable 
Connector Ports
Ground Screw
Main Power 
Access Port
TI12638a
TI12657a