JVC KM-H2500E User Manual

Page of 56
44
Bi-level Pulse
• Return Loss: 
≥30dB to 6 MHz 
• Levels: NTSC: 286mV ± 14mV (40 IRE ±2 IRE) 
PAL: 307mV (43 IRE)
• Rise Times (10-90%): NTSC 140ns ±20ns PAL: 
200ns ±20ns
• Duration: NTSC: 4.7us ±0.1 us PAL: 4.7us ±0.2us
Error Messages
The following error messages may appear when starting your switcher.
GVG100 Protocol Supported Commands
The following tables list the Supported GVG100 commands and controls.
Table 5  Switcher Error Messages
Error Message
Description
Solution
DDR 0 Not Found
DDR 1 Not Found
DDR 0 & 1 Not Found
There is a problem with the switcher DDR 
memory. The switcher may be used but 
many features will be limited or disabled
Re-start your switcher. If the problem 
persists, contact JVC Technical Support 
for assistance.
Upgrade PMC?
Your switcher requires a Panel Module 
Controller (PMC) upgrade as part of a 
software upgrade. The switcher may be 
used without the PMC upgrade but may 
respond in an unpredictable manner
Allow the PMC upgrade to proceed. 
Contact JVC Technical Support for 
assistance if you are unsure about 
upgrading your switcher.
Table 6  GVG100 Supported Commands
Name
MLE/Keyer
Length
Byte Code
Data/Notes
Read MLE Program Bus
MLE
2
41
Read MLE Preset Bus
MLE
2
42
Read Keyer Bus
Keyer
2
43/44
Write MLE Program Bus
MLE
3
C1
<xpt>
An invalid xpt request 
returns a protocol error
Write MLE Preset Bus
MLE
3
C2
<xpt>
An invalid xpt request 
returns a protocol error
Write Keyer Bus
Keyer
3
C3/C4
<xpt>
An invalid xpt request 
returns a protocol error
Read Analog
MLE/Keyer
3
45
<control>
Write Analog
MLE/Keyer
5
C5
<control>
<lsb>
<msb>
Read Light On/off
MLE/Keyer
3
46/47
Write Light On/off
MLE/Keyer
3
C6/C7
<lamp>
Read Wipe Pattern
MLE
2
48
Write Wipe Pattern
MLE
3
C8
<wipe>
Valid wipes are 0-9, as 
per the Wipe Pattern 
button numbers. An 
invalid wipe number 
returns a protocol error.
Read Transition Mode
MLE
2
4A