DEC Switch - This is the declination switch error value set when Utilities / Calibrate Mount  / 
DEC Switch - Cone is carried out. 
• 
RA Switch - This is the R.A. switch error value set when Utilities / Calibrate Mount  / R.A. 
Switch is carried out. 
 
 
Utility Features 
 
Scrolling through the MENU (9) options will also provide access to several advanced utility functions within 
the CGE such as; Mount Calibration, Periodic Error Correction, Hibernate as well as many others. 
 
 
Calibrate Mount
 - In order to optimize the performance and pointing accuracy of 
the CGE mount,  the CGE has built-in calibration routines allowing it to compensate 
for mechanical variation inherent in every German equatorial mount.  Each 
calibration is completely automatic and in most cases only needs to be performed 
once.  It is highly recommended that you take a few minutes to go through the mount 
calibration procedures. 
 
• 
Dec Switch / Cone Calibration – this procedure simultaneously 
records the offset error when the declination switch is found at start-up 
and compensates for "cone" error due to slight misalignments of the 
optical tube and declination axis. For more information on calibrating 
the Dec switch and cone error, see the box called  "Calibrating the 
CGE Mount" in the Startup Procedure section earlier in this chapter.   
 
• 
R.A. Switch Calibration - this procedure records the offset error when 
the right ascension switch is found at start-up.  Calibrating the R.A. 
switch will improve the accuracy of your initial star alignments when 
aligning the telescope. 
 
• 
GoTo Calibration – Goto Calibration is a useful tool when attaching 
heavy visual or photographic accessories to the telescope. Goto 
Calibration calculates the amount of distance and time it takes for the 
mount to complete its final slow goto when slewing to an object.   
Changing the balance of the telescope can prolong the time it takes to 
complete the final slew.  Goto Calibration takes into account any slight 
imbalances and changes the final goto distance to compensate. 
 
 
Move to Switch 
– 
Slews the telescope to locate either its R.A. or declination 
switches. 
 
Home Position – 
The telescopes "home" position is a user-definable position that is used to store the telescope 
when not in use.  The home position is useful when storing the CGE telescope in a permanent observatory 
facility and especially when using the Hibernate feature to maintain a star align over many observing sessions. 
  
Polar Align- 
The CGE has a polar alignment function that will help you polar align your telescope for 
increased tracking precision and astrophotography.  After performing an Auto Two-Star Alignment, the 
telescope will slew to where Polaris should be.  By using the equatorial head to center Polaris in the eyepiece, 
the mount will then be pointed towards the actual North Celestial Pole.  Once Polar Align is complete, you must 
re-align your telescope again using any of the alignment methods described earlier.  To polar align the CGE 
mount in the Northern Hemisphere: 
 
DEC SWITCH / CONE
R.A. SWITCH
GOTO
CALIBRATE MOUNT
R.A. TO SWITCH
DEC TO SWITCH
MOVE TO SWITCH
GOTO
SET
HOME POSTION
POLAR ALIGN
PLAYBACK
RECORD
PEC
LIGHT CONTROL
PRESS UNDO
PRESS "0"
FACTORY SETTING
VERSION
GET ALT-AZ
GOTO ATL-AZ
HIBERNATE
TURN ON/OFF RTC
TURN ON/OFF GPS
UTILITIES