Control elements
7
Footswitch
Footswitch BUGERA FSB104
The  7-pin 
36 
DIN  connector  is  provided  to  connect 
the footswitch cable (included). Then, the cable is 
connected  to  the  FOOTSW(itch)  connector  of  the 
BUGERA  amplifier.  Be  sure  to  make  a  connection 
before switching on the amplifier.
The 
37 
CLEAN switch activates the CLEAN channel. Its 
LED illuminates when the channel is active.
The 
38 
CRUNCH  switch  activates  the  CRUNCH  chan-
nel. Its LED illuminates when the channel is active.
The 
39 
LEAD  switch  activates  the  LEAD  channel.  Its 
LED illuminates when the channel is active.
The 
40 
FX LOOP switch activates the FX LOOP and the 
BOOST  function.  Its  LED  illuminates  when  the  FX 
LOOP is active.
Inside the BUGERA
DANGER!
 
*
High voltage! Risk of death!
High  voltages  of  up  to  500  V  DC  may  be 
present  inside  the  casing  for  long  periods 
after  being  disconnected  from  the  mains. 
To avoid lethal electric shock, do not open 
the  casing.  There  are  no  user-serviceable 
components  inside.  Refer  all  maintenance 
to qualified service personnel. Remove the 
mains cable when the unit is not in use.
The  parts  inside  the  amplifier  operate  at 
 
*
high  voltages  and  high  temperatures.  To 
avoid damage and injury that results from 
fire  or  electric  shock,  do  not  drop  or  spill 
anything into the unit’s casing.
Instructions for qualified service 
personnel only
Remove the backside of the amplifier’s casing to get to 
the valves and the control elements.
These  are  the  sockets  for  the 
41 
12AX7A/B/C  pre-
amp valves.
These are the sockets for the 
42 
6L6 and EL34 power 
amp valves. Please take care that the BIAS SELECT-
switch  (43)  is  set  correctly.  The  models  333  and 
333-212 are supplied with 6L6GC power amp valves 
when it leaves the factory. The models 333XL and 
333XL-212 incorporate EL34 power amp valves.
The 
43 
BIAS  SELECT  switch  allows  the  amplifier  to 
optimally adapt to the used valves (6L6 or EL34).
 
*
The 
44 
BIAS TEST connector lets you connect a volt-
meter  in  order  to  measure  the  power  amp  valves 
(bias adjustment). Make sure that the voltmeter is 
set to direct current (DC).
The 
45 
BIAS ADJUST control is used to make the bi-
as-adjustment. 
Replacing the power amp valves also requires 
 
$
bias adjustment. You should always use sets 
of  four  matched  valves.  The  valves  of  the 
BUGERA Series are ideal for this purpose.
Inside the BUGERA 333