Components 
 
 
 
 
 
 
 
 
Operation 
The pump is worked by a single full movement; by pressing the dispenser head downwards a 1/30 fl. Oz. of 
liquid will be expelled. When first used it may be necessary to prime the pump with several movements. 
Note: This dispenser is NOT designed for use with soaps which contain suspended particles. If these soaps 
are used it will affect the working parts of the dispenser and will negate the warranty
 
 
 
 
 
 
Trouble Shooting 
 
Symptom   
Cause 
  Cure 
No Soap is expelled when 
PUMP not primed 
 
Prime PUMP with several movements 
Dispenser HEAD pressed 
 
 
 
Soap BOTTLE Empty   
Refill Bottle 
 
 
 
Soap Congealed in PUMP 
Lift DISPENSER BODY from 
 
 
(Likely if dispenser has not been  CONNECTOR and run hot water thro’ 
 
 
used for a number of weeks) 
tube while operating PUMP 
 
 
 
Hole in end of FLEXIBLE 
Realign hole using a needle 
 
 
TUBE not in line with SPOUT 
 
 
 
FLEXIBLE TUBE is broken. 
Contact Distributor 
 
 
(Soap seen to leak from body) 
 
PUMP is difficult to move  
Soap Congealed in PUMP 
Lift DISPENSER BODY from 
 
 
(Likely if dispenser has not been  CONNECTOR and run hot water thro’ 
 
 
used for a number of weeks) 
tube while operating PUMP 
 
 
 
PUMP is damaged 
 
Replace PUMP (see Service Section) 
 
 
Service  
It is unlikely that any components will fail in normal use, but should it be necessary, parts are replaceable 
in the assemblies illustrated and are available from your local KWC DISTRIBUTOR. Before attempting to 
replace any parts it is important the instructions below are read and understood. 
 
PUMP replacement 
1.  To replace the PUMP firstly remove assembled BODY, PUMP unit from the CONNECTOR.  
2.  Remove the TUBE from the base of the pump by holding BODY,PUMP unit firmly and pulling TUBE.  
3.  Unscrew the 3 screws securing the BOTTOM LOCATING RING to the body and pull the ring away. 
4.  Again holding the BODY firmly, remove the PUMP by pulling it from the internal PLUNGER. 
5.  Insert new PUMP by pushing it into the PLUNGER. It is important that the PUMP is pushed fully home 
otherwise the dispensing action will be impaired and/or leakage may occur. 
6.  Replace the BOTTOM LOCATING RING and secure with the SCREWS, take care not to over tighten, 
then push TUBE back into PUMP and lower assembled UNIT into CONNECTOR. 
 
Failure to follow above instruction will cause damage to the internal flexible tube.
 
 
 
WE RESERVE THE RIGHT TO CHANGE PRODUCT 
              AND SPECIFICATIONS WITHOUT PRIOR NOTICE
 
 
 
 
 
 
 
Bottle
Connector 
Assembly
Spacer
Washer
Dip Tube
Body and 
Pump
Assembly