When the input select switch (LINE / MIC) is set to “LINE”, 
“ ” is shown. When it is set to “MIC”, the microphone 
power supply status is shown.
For the T12 status, depending on whether the T12 power 
supply function is enabled or disabled, the icon looks dif-
ferently as below. 
On the input status display, not only you can see the cur-
rent status of the following switches, but also you can 
disable or enable the T12 power supply function. The fol-
lowing shows the default setting when the unit is shipped. 
T12
DM
P48
MIC
T12 disabled/enabled setting
(1)  
While the input status display is shown, press    
 
the [EDIT] key long enough.
 
The “
” icons change to the fast flashing “ ” icons. 
 
You can now edit enabled/disabled setting of the T12 
 
power supply function. (“ ” shows “Enable” setting 
 
that is the default). 
<Note>: In the following description, it is assumed that the 
input select switches (LINE / MIC) are set to “MIC” and the 
Microphone power supply switches are set to “DM” on the 
left side panel. In this condition, the input status display looks 
as below.
When the T12 power supply function is disabled
When the T12 power supply function is enabled (default)
(2)  
Press the [+] key to change “ ” to “ ”, and    
 
press the [EDIT] key long enough.  
 
The T12 power supply function is now disabled. 
 
The display returns to the previous condition. (If you press  
 
the [-] key while the “ ” icons are flashing, they are  
 
changed to “ ”.)
Flashing
• Microphone power supply switch status
<Memo>: The T12 disabled/enabled setting remains 
even after you turn off the unit. 
The following icons are shown according to the switch setting.
Input status display
• Input select switch status
• [HPF] switch status
• [TO ST BUSS] switch status
Switch setting
Icon
LINE
Switch setting
Icon
T12
DM
P48
Switch setting
Icon
ON (40~300Hz)
OFF
Switch setting
Icon
ON
OFF
Switch setting
Icon
Left side panel
Left side panel
Left side panel
Front panel
Some condenser microphones used for video field re-
cording, such as the Sennheiser 416T, require T12 (AB-
12V) power. The FM-3 can supply the T12 power.
Unlike the phantom power (P48), connecting a dynamic 
microphone to the input channel where the T12 power is 
supplied may destroy the microphone. To prevent such 
an accident, you can disable the T12 power supply func-
tion. If you do not use the T12 power supply function in 
your circumstance, it is recommended to disable the T12 
power by following the procedure below. When shipped, 
the T12 power supply function is disabled. 
Flashing