3. Setup 
   
 
AC Power 
 
Each MVP™ has an auto-ranging power supply that works  with an input voltage range of 
100~240 VAC, 50/60 Hz. 
Make sure that you are connecting the MVPs to the proper voltage, as specified  in this 
User Manual and on the product’s specification sticker. 
 
 
 
 
 
Always connect this product to a protected circuit with an appropriate electrical 
ground to avoid the risk of electrocution or fire. 
 
 
 
   
To determine the power requirements for each MVP™  in the series, refer to the label 
affixed to the  product.  You can also refer to the 
Technical  Specifications
  chart  in this  
manual.  
The listed current rating indicates the maximum current draw during normal operation. For 
more information, you may download Sizing  Circuit Breakers  from the CHAUVET® 
website: 
www.chauvetpro.com
 
 
 
 
 
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if 
the rheostat or dimmer channel serves only as a 0% to 100% switch. 
   
 
AC Plug 
 
Each MVP™ comes with a power linking cord to connect power between panels; however, 
the power input cord is not included.  
The power input cord must  be purchased separately. CHAUVET® recommends the 
Neutrik®  powerCON®  extension  cable, item number  PCEXT50FT,  available from 
CHAUVET®. 
This cable has a powerCON connector to connect to the MVP™ and a bare plug for power 
input. Use the table below as a reference to wire a new plug. 
 
 
 
   
Connection 
Wire (US) 
Wire (Europe) 
Screw Color 
AC Live 
Black 
Brown 
Yellow or Brass 
AC Neutral 
White 
Blue 
Silver 
AC Ground 
Green/Yellow 
Green/Yellow 
Green 
   
 
Power Linking 
 
All three panels in the Series  support power linking.  Refer to the following table for 
specifications on each panel.  
 
 
 
 
MVP™ 12 
MVP™ 18 
MVP™ 37.5 
@
 120 V, 60 Hz 
13 
@
 208 V, 60 Hz 
11 
11 
20 
@
 230 V, 50 Hz 
12 
12 
22 
 
 
 
 
 
 
Please refer to all applicable local codes and regulations for the proper installation 
of this product.