Avaya S8300 User Manual

Page of 370
5
Upgrading an Existing G700 with an S8300 — R1.x to R2.0
Complete the Upgrade Process (S8300 is the Primary Controller)
260
Installation and Upgrades for G700 and S8300
December 2003
Complete the Upgrade Process 
(S8300 is the Primary Controller)
Telnet to the S8300 (primary controller) and open a SAT session to complete the following procedures.
Check Media Modules 
1
Type 
list configuration all
 and press 
Enter
2
Verify that the software is communicating with all media modules and that all media modules are 
listed in the reports. 
3
Make test telephone calls to verify that Communication Manager is working. 
Enable Scheduled Maintenance 
1
Type 
change system-parameters maintenance
 and press 
Enter
2
Ensure that the 
Start Time
 and 
Stop Time
 fields’ administration is the same as before the 
upgrade. 
Busy Out Trunks 
1
Busy out trunks that were busied out before the upgrade (see 
Check for Translation Corruption 
1
Type 
newterm
 and press 
Enter
If you do not get a login prompt and see the following message: 
Warning: Translation corruption detected
 
follow the normal escalation procedure for translation corruption before continuing the upgrade. 
Resolve Alarms 
1
On the Maintenance Web Interface, under Alarms click 
Current Alarms
 to examine the alarm 
log. 
2
If any alarms are listed, click Clear All.
3
Resolve new alarms since the upgrade through Communication Manager using the appropriate 
maintenance book.