Upgrading an Existing G700 without an S8300
Install New Firmware on the G700 Media Gateway
310
Installation and Upgrades for G700 and S8300
December 2003
Install New Firmware on the G700 Media Gateway
NOTE:
The Upgrade Tool performs this task automatically.
Follow the procedures in this section to install firmware on the G700 processors and media modules
Firmware Installation Procedures
Install New Firmware on the P330 Stack 
Processor
Install P330 stack processor firmware
1
Access the P330 stack processor.
1
At the P330-1(configure)# prompt, type 
copy tftp SW_image <file> EW_archive <ew_file> <tftp_server_address> 
<Module#>
 
where 
<file> is the full-path name for the image file with format and vintage number similar to 
viisa3_8_2.exe, 
<ew_file> is the full-path name for the embedded web application file with format similar to 
p330Tweb.3.8.6.exe, 
<tftp_server_ip_address> is the IP address of the TFTP server, and
<Module#> is the number, 1 through 10, of the media gateway in the stack. If there is only one 
G700 Media Gateway, the number is 
1
.
2
To verify that the download was successful when the prompt returns:
— type 
show image version <module #> 
and check the version number in the Version 
column for Bank B. 
— type 
dir
 
<module #> 
and check the version number in the ver num column for the 
EW_Archive file.
3
Type 
reset <module #>
Install New Firmware on the G700 Media 
Gateway Processor
Install MGP firmware
1
At the P330-1(configure)# prompt, type 
session mgp
 to reach the G700 Media Gateway 
processor. 
2
Type 
configure
 at the
 
MG-???-1(super)# prompt to enter configuration mode, which will change 
the prompt to MG-???-1(configure)#.