iOptron 9801-W User Manual

Page of 38
 
 
21
•  Using the battery? Are the batteries 
installed correctly? Are the batteries 
fresh? How long have they been 
used? (frequent slew and GOTO will 
deplete battery power very quickly) 
•  Using AC or DC adapter? Check the 
plugs to the mount and to the power 
outlet. 
•  Using extension cord? Make sure 
the cord is in good condition. Power 
drop along the extension cord was 
known to cause the problem. Also 
check all the plugs and connections. 
(4)  If the telescope does not respond to 
commands, set the power switch to OFF 
and then back to ON.  
(5)  If the telescope does not slew after 
power is applied or if the motor quits or 
stalls, verify that there are no physical 
obstructions that would impede 
telescope movement. 
Cannot seem to focus (No image 
appears in the eyepiece): 
(1)  Confirm that the dust cap has been 
removed from the telescope. 
(2)  Keep turning the focus knob. Your 
telescope has a fine focusing 
mechanism which allows you to focus 
an image very precisely. However, this 
means that you may have to rotate the 
focus knob 20 to 40 complete turns to 
achieve focus, particularly the first 
time you use your telescope. After that, 
fewer turns will be needed. 
Images through the eyepiece appear 
unfocused or distorted: 
 
(1)  The magnification used may be too high 
for the seeing conditions. Back off to a 
lower power eyepiece.  
(2)  If inside a warm house or building, move 
outside. Interior air conditions may 
distort terrestrial (land) or celestial 
images, making it difficult, if not 
impossible, to obtain a sharp focus. For 
optimal viewing, use the telescope 
outside in the open air instead of 
observing through an open or closed 
window or screen.  
(3)  If viewing a land object on a warm day, 
heat waves distort the image.  
(4)  The optics within the telescope need 
time to adjust to the outside ambient 
temperature to provide the sharpest 
image. To "cool down" the optics, set 
the telescope outside for 10 to 15 
minutes before observing begins. 
Error Message “Warning! Motor driver 
overloaded.” 
 
(1)  Check the hand controller cord. Unplug 
it and re-plug into, or plug it into another 
HBX port. 
(2)  Check the power source. 
The telescope does not GOTO the right 
object, or the alignment is always wrong: 
 
(1)  Leveling (very important). 
(2)  Site information (minutes ahead or 
behind UT, DST). 
(3)  Check the power source. 
6.4. iOptron Customer Service 
If you have a question concerning your 
telescope, contact the iOptron Customer 
Service Department. Customer Service 
hours are 9:00 AM to 5:00 PM, Easter Time, 
Monday through Friday. In the unlikely 
event that the telescope requires factory 
servicing or repairs, write or call the iOptron 
Customer Service Department first, before 
returning the telescope to the factory, giving 
full particulars as to the nature of the 
problem, as well as your name, address, 
and daytime telephone number. The great 
majority of servicing issues can be resolved 
by telephone, avoiding return of the 
telescope to the factory. 
It is also suggested to send technical 
questions to support@ioptron.com.