Honeywell CM67 User Manual

Page of 7
CM67
CHRONOTHERM
EN0R 8498 R2 11/98
2
SPECIFICATIONS
CM67 CONTROLS/DISPLAY LAYOUT
Batteries
:
2 x 1.5 V IEC LR6 (AA) Alkaline cells
Battery life
:
4 years typical (Duracell MN1500) for
applications with loads <3A
:
3 years typical for electric heat
applications (>3A, <8A)
Battery
replacement
:
Program retained in EEPROM
Switch type
:
SPDT (potential free)
Electrical rating
:
230 V~, 50...60 Hz, 0.5 A to 8 A resistive
0.5 A to 3 A inductive (0.6 pf)
24 V~, 50...60 Hz, 0.5 A to 8 A resistive
0.5 A to 3 A inductive (0.6 pf)
Time display
:
24 hour or 12 hour AM/PM format
Time keeping
accuracy
:
Typically better than 10 minutes per year
Program
:
7-day with 6 daily time and temperature
level changes
Time setting
resolution
:
Time of day - 1 minute
Program - 10 minute steps
Sensing element
:
100K (@ 25
o
C ) NTC thermistor
Temperature
setting range
:
Program : 5 to 30
o
C in 0.5
o
C steps
Frost
: 5
o
C or equal to lower limit
(5
o
C to 16
o
C). Frost protection does not
work in cooling mode
Temperature
control accuracy
:
±0.5 K (nominal) @ 20
o
C, 50% load
3 K
/hour
Room
Temperature
display range
:
From 0
o
C to 40
o
C
Control form
:
P + I (Proportional + Integral)
Minimum ON
time
:
10% of cycle time (min one minute),
adjustable to 2 to 5 min (see installer set
up)
Cycle rate
:
3, 6( default), 9, 12. Selectable through
the installer set up mode.
Wiring
:
Terminal block capable of accepting
wires up to 2.5 mm
2
Wire access
:
Mains wiring - rear, left or below
Low voltage wiring - rear, left or below
Dimensions
:
130 x 87R(82L) x 29 mm (w x h x d)
130 x 172 x 29 mm (w x h x d) (flap
open)
Environmental
:
Operating temperature range 0 to 40
o
C
Shipping and storage temperature range
-20 to 55
o
C
Humidity range 0 to 90% rh, non-
condensing
Approvals
:
Designed to meet European EN
approvals EN60730-1(1995), EN55014-1
(1997), EN55014-2 (1996)