Honeywell CM67 User Manual

Page of 7
CM67
CHRONOTHERM
EN0R 8498 R2 11/98
6
DIMENSIONS
LOCATION
The
CM67
Chronotherm is the temperature control element
in the heating/cooling system and MUST be located in a
position with good air circulation at average room
temperature on an inside wall 1.5 metres above the floor
level. Do not position the
CM67
Chronotherm near sources
of heat (radiators, hot air vents, TV or lights), near doors or
windows, or in direct sunlight.
MOUNTING
The
CM67
Chronotherm can be mounted directly on the wall
surface or on an electrical wallbox.
WIRING
The
CM67
Chronotherm is designed for fixed wiring only and
must be installed in accordance with latest l.E.E. regulations.
Ensure the wiring connection to the supply is via a fuse rated
at no more than 8 amps and a Class "A" switch (having
contact separation of at least 3 mm in all poles).
IMPORTANT
1. The installer must be a trained service engineer
2. Disconnect the power supply before beginning
installation
INSTALLATION