Triggering Measurements
Trigger Mode and Measurement Speed 
There are two generalized scenarios which can be described for GPIB triggering 
control. The first is to have the Test Set return measurement results as fast as 
possible and assume that the control program will handle all transient settling and 
value tolerance activities. The second scenario is to have the Test Set return the 
most reliable, accurate, fully settled measurement results that it can, even if it 
takes some time to do this. 
Trigger Mode Settings for Fastest Measurements 
Use the following Test Set configuration and trigger mode settings for the fastest 
possible measurement speed. See 
 for more information on improving measurement throughput. 
1. Range hold all auto-ranging and auto-tuning functions and set ranges and frequency 
through GPIB. This avoids autoranging/autotuning delays. 
2. Use REPetitive RETRiggering. This avoids Trigger Event processing delays. 
3. Use FAST SETTling. This avoids the signal transient settling delays.
1
 
4. Turn off all measurements that are not required. This avoids any delays caused by 
contention for measurement resources within the Test Set. 
Trigger Mode Settings for Most Reliable Measurements 
Use the following Test Set configuration and trigger mode settings to get the most 
accurate, most reliable, fully settled measurement results. See 
 for more information on improving 
measurement throughput. 
1. Turn on all autoranging and autotuning functions. (This is the Test Set’s default turn-on 
and PRESET state.) 
2. Use SINGle RETRiggering. 
3. Use FULL SETTling. 
4. Individually trigger each measurement. 
1.
Using FAST settling increases the possibility that transient signal conditions which 
occur during the measurement cycle will be included in the measurement result.