Emerson 2468CD User Manual

Page of 186
Hydrastep 2468CB and 2468CD Manual 
Relay Output Board Option 
24685034
 
3a-1 
3a 
2468 - Relay Output Board Option 
 
Contents 
 
Page No. 
3A.1 GENERAL 
DESCRIPTION 
3A.2 INSTALLATION 
3A.2.1 
STORAGE & PRE-INSTALLATION INSPECTION ................................... 3 
3a.2.1.1 Storage Area ............................................................................... 3 
3a.2.1.2 Pre-Installation Inspection 
........................................................... 3 
3A.2.2 MECHANICAL 
INSTALLATION ................................................................ 3 
3a.2.2.1  Fitting the Nylon Spacers to the Relay Output Board ................. 4 
3a.2.2.2  Mounting the Relay Output Board on to the Input Board ............ 4 
3A.2.3 ELECTRICAL 
INSTALLATION ................................................................. 5 
3a.2.3.1 PCB Interconnections ................................................................. 5 
3a.2.3.2 Relay Output Connections .......................................................... 5 
3A.3 
RELAY BOARD CONFIGURATION 
3A.3.1 RELAY 
OUTPUT BOARD ......................................................................... 7 
3a.3.1.1 Configuring the Relay Output Board ........................................... 7 
3a.3.1.2 Electrode/Relay Selection (Relays RL1, RL2, RL3 & RL4) - 
SW1 To SW4 .............................................................................. 7 
3a.3.1.3  Relay Energisation (‘In Steam’ or ‘In Water’) - SW5 ................... 8 
3a.3.1.4 Electrode/Alarm Operation (RL1 Function Only) - SW6 ............. 8 
3a.3.1.5 System Fault Output ................................................................... 8 
3A.3.2 ALARM 
AND 
TRIPPING FACILITIES ....................................................... 9 
3a.3.2.1 Philosophy 
................................................................................... 9 
3a.3.2.2 Relay Interconnections for Alarm/Tripping Systems ................... 9 
3a.3.2.3  ‘One out of Two’ Relay Alarm System ...................................... 10 
3a.3.2.4  ‘Two out of Two’ Relay Alarm System ...................................... 11 
3a.3.2.5  ‘Two out of Four’ Relay Alarm System ..................................... 12 
3a.3.2.6  ‘Two out of Three’ Relay Alarm System ................................... 14 
3A.4 COMPONENT 
REPLACEMENT 15 
3a.4.1 REPLACEMENT 
OF NYLON SPACERS ................................. 15 
3a.4.2 
PARTS LIST - RELAY OUTPUT BOARD 24680504 ................ 15 
3A.5 SPECIFICATION 
16