KitchenAid KBZU122VSS User Manual

Page of 48
12
The gas supply line shall be equipped with an approved shutoff 
valve. This valve should be located in the same area as the side 
burner and should be in a location that allows ease of opening 
and closing. Do not block access to the shutoff valve. The valve 
is for turning on or shutting off gas to the side burner.
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The 
qualified Natural gas technician shall provide the Natural gas 
supply to the selected side burner location in accordance with 
the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest 
edition, and local codes. For conversion to Natural gas, the 
Natural gas conversion kit supplied with the side burner must be 
used.
IMPORTANT: The gas installation must conform with local 
codes, or in the absence of local codes, with the National Fuel 
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
To convert to Natural gas, the Natural Gas Conversion Kit 
supplied with the side burner must be used. Follow instructions 
for converting to Natural gas in the “Gas Conversions” section.
The gas supply line shall be equipped with an approved shutoff 
valve. This valve should be located in the same area as the side 
burner and should be in a location that allows ease of opening 
and closing. Do not block access to the shutoff valve. The valve 
is for turning on or shutting off gas to the side burner.
Gas Connection Requirements
For Models Equipped for Natural Gas
Natural Gas
Built-in side burner models are equipped for use with Natural 
gas. They are design-certified by CSA International for LP 
(propane or butane) gases with appropriate conversion.
Built-in models are set for Natural gas use and have a pressure 
regulator with ½" female pipe threads.
The supply line shall be equipped with an approved shutoff valve. 
This valve should be located in the same area as the side burner 
and should be in a location that allows ease of opening and 
closing. Do not block access to the shutoff valve. The valve is for 
turning on or shutting off gas to the side burner.
LP Gas Conversion Using a Local LP Gas Supply
Conversion must be made by a qualified person. A qualified 
Natural gas technician shall provide the LP gas supply to the 
selected side burner location in accordance with the National 
Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, and local 
codes.
A. Gas supply line
B. Shutoff valve “open” position
C. To side burner
A. New CSA International approved 
“outdoor” flexible gas supply line  
B. Rear of side burner
C. To Natural gas supply
A. Gas supply line
B. Shutoff valve “open” position
C. To side burner
A
B
C
B
C
A
A
B
C
A. Side burner gas pipe
B. New CSA International approved 
“outdoor” flexible gas supply line 
C. Rear of side burner
D. To Natural gas supply