Availability
Before installing this machine, consider the 
availability and proximity of the required power 
supply circuit. If an existing circuit does not 
meet the requirements for this machine, a new 
circuit must be installed to minimize the risk 
of electrocution, fire, or equipment damage, 
installation work and electrical wiring must be 
done by a qualified electrician in accordance with 
all applicable codes and standards.
Electrocution,  fire,  or  equipment 
damage  may  occur  if  the  machine 
is  not  correctly  grounded  and 
connected to the power supply.
Full-Load Current Rating
The full-load current rating is the amperage a 
machine draws at 100% of the rated output power. 
On machines with multiple motors, this is the 
amperage drawn by the largest motor or sum of all 
motors and electrical devices that might operate 
at one time during normal operations.
Full Load Current Rating .................. 12 Amps
The full-load current is not the maximum amount 
of amps that the machine will draw. If the 
machine is overloaded, it will draw additional 
amps beyond the full-load rating.
If the machine is overloaded for a sufficient length 
of time, damage, overheating, or fire may result—
especially if connected to an undersized circuit. To 
reduce the risk of these hazards, avoid overloading 
the machine during operation and make sure it is 
connected to a power supply circuit that meets 
the requirements in the following section.
Circuit Information
A power supply circuit includes all electrical 
equipment between the main breaker box or fuse 
panel in your building and the incoming power 
connections at the machine. This circuit must be 
sized to safely handle the full-load current drawn 
from the machine for an extended period of time.
For your own safety and protection of property, 
consult a qualified electrician if you are unsure 
about  wiring  practices  or  electrical  codes  in 
your area.
Note: The circuit requirements listed in this 
manual apply to a dedicated circuit—where only 
one machine will be running at a time. If this 
machine will be connected to a shared circuit 
where multiple machines will be running at the 
same time, consult a qualified electrician to 
ensure that the circuit is properly sized for safe 
operation.
Circuit Requirements
This machine prewired to operate on a 220V power 
supply circuit that has a verified ground and meets 
the following requirements:
Nominal Voltage .......................... 220V/240V
Cycle ...............................................60 Hz
Phase ..................................... Single-Phase
Circuit Rating ................................ 15 Amps
Plug/Receptacle .......................... NEMA 6-15