DMS-MTX DualMode Metrocell Cell Site Description
 
6
 
Datafilling a Metro Cell Site
 
Datafill Overview
 
This section outlines the differences which you should consider when 
datafilling a Metro site. It makes no attempt at dealing with the entire datafill 
procedure and assumes that you are familiar with the MTX Cell Site Datafill 
Procedures. Please refer to 
 
NTP 411-2131-461 ICP Datafill Guide
 
 for 
information concerning the entire Cell Site Table Datafill.
A Metro Cell site looks for all intensive purposes like any other ICP/ICRM 
cell site to the MTX. It uses all the same tables, loads, and parameters as do 
the previous ICP/ICRM methods. The outstanding difference, which is 
apparent, is that more Trunks and DSPMs will be required to service the 
additional radios that the Metro RF frame is equipped with. The following 
datafill tables will be addressed in the view of differences to keep in mind 
when datafilling a Metro Cell Site:
 
Table 6-1
Datafill differences of the Metrocell from an NT800DR cell
Table
Metro differences 
 
CLLI
More trunks should be assigned as each RF frame can be 
equipped with 8 more radios than a standard macrocell frame.
ACUALM
PA Fan Alarms are laid out differently with the new RF frame.
CCHINV
The RF frame location of the DRU should be correctly identified 
in relation to the ICRM P-side card port number.
LCRINV
The RF frame location of the DRU should be correctly identified 
in relation to the ICRM P-side card port number.
VCHINV
The RF frame location of the DRU should be correctly identified 
in relation to the ICRM P-side card port number.