110/220V Operation
SECTION 2: CIRCUIT REQUIREMENTS
Amperage Draw
The  Model  G7947/G7948  motor  is  prewired  to 
110V,  but  can  be  rewired  to  220V.  The  machine 
draws the following amps under load:
G7947 at 110V ....................................... 10 Amps
G7947 at 220V .........................................5 Amps
G7948 at 110V ....................................... 15 Amps
G7948 at 220V ..................................... 7.5 Amps
Circuit Requirements
Only connect your machine to a circuit that meets 
the  requirements  below.  Always  check  to  see  if 
the  wires  and  circuit  breaker  in  your  circuit  are 
capable  of  handling  the  amperage  draw  from 
your machine, as well as any other machines that 
could be operating on the same circuit. If you are 
unsure, consult a qualified electrician. 
G7947 110V Minimum Circuit ..................15 Amp
G7947 220V Minimum Circuit ..................10 Amp
G7948 110V Minimum Circuit ..................20 Amp
G7948 220V Minimum Circuit .................10 Amp
Figure 3. 6-15 plug and outlet.
NOTICE
The  Model  G7947/G7948  is  prewired  for 
110V  operation.  For  220V  operation,  you 
must  rewire  your  motor.  A  qualified  elec-
trician  must  inspect  any  rewiring  to  this 
machine before putting it into operation.
Plug Type
The Model G7947/G7948 comes prewired with a 
NEMA 5-15 plug. If you wish to rewire the motor 
to 220V we recommend using the following plug 
(see 
Figure 3 for an example):
220V Plug & Receptacle ................ 6-15 or L6-15