OPERATION
When  to  charge  the  Power  Plus  battery  pack
Charge your battery pack before you use your tool for the first time and when
your tool no longer performs with the power and torque needed for the job.
Never completely discharge the battery pack.
New  battery  packs  reach  full  loading  capacity  after  4-5  chargings  and
dischargings.    Battery  packs  which  have  not  been  used  for  some  time
should be recharged before use.
Standard  charging  times
Standard charging time is approximately one hour.  Charging time varies
depending  on  the  battery  temperature,  charge  needed  and  the  type  of
battery  pack  being  charged.    For  example,  if  the  battery  pack  does  not
require a full charge, the charging time will be less than one hour.
Effects  of  temperature  on  charging
Battery packs are affected by temperature.  The charger will sense battery
temperature  and  will  charge  the  battery  at  the  most  rapid  rate  when  its
temperature is between 41°F (5°C) and 113°F (45°C).  When the battery
temperature is outside of this range, charging will occur at a slower rate
to prevent damage to battery.
Automatic  start
When a hot or cold battery pack is inserted into the charger, charging will
begin  automatically  once  the  battery  reaches  the  correct  charging
temperature.
Maintenance  charge
Batteries discharge at a rate of about 1% per day. The Maintenance Charge
feature  keeps the battery pack fully charged when the battery pack is stored
in a charger that is plugged in.  The Maintenance Charge automatically begins
after  the  battery  pack  is  fully  charged.  During  Maintenance  Charge,
the control light will be off.
Connect Charger to AC
Power Source
Light
Off
Insert Battery
Flashing
Light
Charge pending until
battery temperature is
below  140°F (60°C).
Battery temperature
41°F  - 113°F (5°C - 45°C)
Fast charging
Continuous
Light
Battery too cold
less than 14°F (-10°C)
Flashing
Light
Battery too hot
over 140°F (60°C)
Charge pending until
battery temperature is
above  14°F (-10°C).
Battery temperature
14°F - 41°F (-10°C - 5°C) or 113°F - 140°F (45°C - 60°C)
Charging at a slower rate
Charger Ready
Light
Off
Battery is charged/
Maintenance charging
Charging  the  Power  Plus  Battery  Pack
Charge  only  MILWAUKEE  9.6,  12,
14.4  and  18  Volt  Power  Plus  battery
packs  in  this  charger.  Other  types
of  batteries  may  explode  causing
personal  injury  and  damage.
WARNING!