Operating in Shore Power Mode
Status LED During Inverter Mode
The following summarizes the behavior of the Status LED during 
Inverter mode.
Table 3 Status LED during Inverter Mode
Status 
LED
Display 
Screen
Condition
Solid 
YELLOW
.
(where 12.8 is 
an example of 
battery 
voltage)
Select button is pressed to display Input 
Battery Voltage.
The Input Battery Voltage LED lights up.
Value in display screen is shown as Volts.

(where 11 is 
an example of 
current)
Select button is pressed to display Input 
Current. 
The Input Current LED lights up.
Value in display screen is shown as Amps.
.
(where 0.85 is 
an example of 
output power 
in Kilowatts)
Select button is pressed to display Output 
Power. 
The Output Power LED lights up.
Value in display screen is shown as 
Kilowatts.
through

Warning condition detected while AC 
output power is still available. 
See Table 7, “Error Codes Displayed on the 
Display Panel Screen” on page 35.
Solid RED through

Fault condition detected and AC output 
power is not available. The unit will sound 
an alarm and will shutdown completely 
within 30 seconds
a
. A five-minute delayed 
shutdown is available in some models
b
.
Off
Off
Inverter is OFF.
Off (or 
Yellow)
.
No communication between the Freedom 
HF and the Display Panel because the 
battery voltage was too low to start the 
Inverter.
a. Available in all models except Freedom HF 1500 and 1800 T. See page 22.
b. Available only for the Freedom HF 1500 and 1800 T models. See page 23.
Table 3 Status LED during Inverter Mode
Status 
LED
Display 
Screen
Condition
Freedom HF InvChg Owners Guide.book  Page 19  Tuesday, April 29, 2014  12:10 PM