Xantrex Technology 806-1055-02 User Manual

Page of 62
38
Freedom HF Owner’s Guide
Troubleshooting Reference
ELECTRICAL SHOCK AND ENERGY HAZARD
Do not disassemble the Freedom HF. It does not contain any user-
serviceable parts. Attempting to service the unit yourself could 
result in an electrical shock or burn.
Failure to follow these instructions can result in death or serious 
injury.
Table 8 Troubleshooting Reference
Problem
Possible Cause
Solution
Battery charging current is lower than the 
charging set point during bulk charge mode.
Ambient (environment) temperature is 
high.
Do not be alarmed, the unit is performing normally. The 
charging current automatically de-rates at high ambient 
temperature.
Improve ventilation. Make sure the unit’s ventilation openings 
are not blocked.
Alarm does not sound when an error is 
encountered.
Alarm is turned OFF.
Press and hold the Select button for two seconds to disable (or 
enable) the audible alarm. See “Display Panel Operation” on 
page 15.
Freedom HF InvChg Owners Guide.book  Page 38  Tuesday, April 29, 2014  12:10 PM