Freedom Inverter/Charger Operation
Display Panel Operation
The Freedom HF features a display panel with three-digit LED 
display to show inverter, AC source, and battery status information.
Feature Description
1
Inverter Power button
Press and hold for one second to turn the Freedom HF’s 
Inverter function ON or OFF (when AC Shore Power is 
NOT present.)
Press and hold for five seconds to adjust feature settings. 
Go back to page 11 for instructions.
FREEDOM HF
Input Voltage(V)
Select
STATUS
Battery
Fault
Utility
Input Current (A)
Output Power (kW)
4
1
2
3
See NOTE in Feature # 4.
2
Three-digit LED display screen shows status information 
and fault codes.
3
Status LED Indicates the mode of operation with a three-
color LED. 
Green pertains to Utility status.
• Solid indicates the Freedom HF is in shore power 
mode and battery is fully charged.
• Flashing indicates the Freedom HF is in shore power 
mode and the unit is currently charging the battery.
Yellow pertains to Battery status.
• Solid indicates the Freedom HF is in inverter mode 
and using the battery to provide AC power.
• Flashing indicates the Freedom HF is in inverter mode 
but AC shore power is detected thus transferring to 
shore power mode within 20 seconds.
Red indicates a Fault condition and the Freedom HF has 
shut down. See “Troubleshooting Reference” on page 38.
Feature Description
Freedom HF InvChg Owners Guide.book  Page 15  Tuesday, April 29, 2014  12:10 PM