Operating During Transition Between Shore Power and Inverter Mode
However, when the internal temperature drops and falls within 
normal operating temperature, the Freedom HF will recover 
automatically and will continue inverting.
During AC shore power mode, when the Freedom HF’s charger 
temperature starts to approach its limit, the charging current will be 
reduced to 10 amps (Freedom HF 1000 models) or 20 amps 
(Freedom HF 1500/1800 models). 
The Freedom HF also monitors the internal transfer relay 
temperature. It automatically turns on the fan when the relay starts 
to approach its preset temperature limit and turns off when it cools 
down. If the relay exceeds its preset temperature limit, the display 
shows a fault code . See “To reset error codes  to :” on 
page 37.
Trouble Loads
Some appliances, including the types listed below, may be damaged 
if they are connected to the Freedom HF:
Speed controllers found in some fans, power tools, kitchen 
appliances, and other loads may be damaged.
Some chargers for small rechargeable batteries can be 
damaged. See “Precautions for Using Rechargeable 
Appliances” on page viii
 for details.
Metal halide arc (HMI) lights can be damaged.
EQUIPMENT DAMAGE
Some equipment may be damaged by the Freedom HF’s modified 
sine wave output, which has a different wave form than utility-
supplied electricity.
Failure to follow these instructions can damage the unit and/or 
damage other equipment.
IMPORTANT: If you are unsure about operating any device with the 
Freedom HF, contact the manufacturer of the device to ensure that it is 
compatible with the modified sine waveform.