Installing the Inverter/Charger
DC Grounding
The Chassis Ground point on the inverter/charger is used to connect 
the chassis of the inverter/charger to your system’s DC grounding 
point, as required by regulations for some installations. Use copper 
wire that is either bare or provided with green/yellow insulation.
The grounding guideline given below assumes you are using the 
code-compliant DC supply cable and fuse sizes indicated on 
page 13. If you are using different sizes, refer to the applicable code 
for DC grounding detail.
To connect the chassis ground:
1.
Using the appropriate wrench, loosen the nut on the chassis 
ground point bolt shown in Figure 9.
2.
Connect the grounding cable between the chassis ground point 
and the DC grounding point for your system.
In an RV or vehicle installation, the DC grounding point will 
usually be the vehicle chassis or a dedicated chassis ground 
bus.
For marine installations, refer to the applicable local code for 
marine DC grounding detail.
3.
Tighten the nut to a torque of 1.47–1.7 Nm.
Figure 9 DC Wiring and DC Grounding
DOM
 
SW
    
3012
rter     A
C/
n      
Cha
rge   F
ault
012
Chassis ground point
Freedom SW 3K2K 230V InvChg Install Guide.book  Page 32  Friday, June 20, 2014  9:11 AM