Extension Cords
Since  this  machine  must  be  permanently  con-
nected  to  the  power  supply,  an  extension  cord 
cannot be used.
Connection Type
Figure 1. Typical setup of a permanently 
connected machine.
Power
Source
Locking
Disconnect Switch
Machine
Ground
Ground
Conduit
Conduit
A permanently connected (hardwired) power sup-
ply is typically installed with wires running through 
mounted  and  secured  conduit.  A  disconnecting 
means,  such  as  a  locking  switch  (see  following 
Figure),  must  be  provided  to  allow  the  machine 
to  be  disconnected  (isolated)  from  the  power 
supply  when  required.  This  installation  must  be 
performed by an electrician in accordance with all 
applicable electrical codes and ordinances.
Serious injury could occur if you connect 
the machine to power before completing the 
setup process. DO NOT connect to power 
until instructed later in this manual.
Grounding Instructions
In  the  event  of  a  malfunction  or  breakdown, 
grounding  provides  a  path  of  least  resistance 
for electrical current to reduce the risk of electric 
shock.  A  permanently  connected  machine  must 
be connected to a grounded metal permanent wir-
ing system; or to a system having an equipment-
grounding conductor. All grounds must be verified 
and  rated  for  the  electrical  requirements  of  the 
machine.  Improper  grounding  can  increase  the 
risk of electric shock!