Grizzly G0673 User Manual

Page of 56
-16-
g0671/g0672/g0673 dust Collector
SECTiON 2: CiRCUiT REQUiREMENTS
full Load amperage Draw
g0671 @ 220V ..................................... 32 Amps 
g0672 @ 220V ..................................... 34 Amps
g0673 @ 220V ..................................... 30 Amps
g0673 @ 440V ..................................... 15 Amps
NOTICE
The Model G0671/G0672/G0673 is prewired 
for 220v operation. if you plan to use your 
Model  G0673  at  440v,  you  MUST  have  a 
qualified  electrican  perform  the  440v  con-
version described on this page.
Operation
Serious  personal  injury  could  occur  if  you 
connect the machine to power before com-
pleting the setup process. DO NOT connect 
the  machine  to  the  power  until  instructed 
later in this manual.
Electrocution or fire could 
result  if  machine  is  not 
grounded  and  installed  in 
compliance with electrical 
codes.  Compliance  MUST 
be  verified  by  a  qualified 
electrician!
figure 6. hardwired locking disconnect switch.
8dcYj^i
id
BVX]^cZ
8dcYj^i
id
EdlZgHdjgXZ
hardwired locking 
disconnect switch
power Connection Device
We  recommend  having  an  electrician  hardwire 
the machine (using a metal conduit setup) directly 
to a locking disconnect switch (
figure 6), which is 
directly connected to the power source.
g0671 Minimum Circuit size .................40 Amps
g0672 Minimum Circuit size .................50 Amps
g0673 Minimum Circuit size (220V) .....40 Amps
g0673 Minimum Circuit size (440V) .....20 Amps
the  Model
 
g0673  can  be  converted  for  440V 
operation. this conversion job consists of discon-
necting the dust collector from the power source, 
changing  the  magnetic  switch,  and  rewiring  the 
motor for 440V operation, as shown on 
page 42. 
the necessary magnetic switch for this procedure 
can  be  purchased  by  calling  grizzly  Customer 
service  at  (800)  523-4777  and  ordering  Model 
g8296 (3-phase 440V 10hp Mag switch).
All wiring changes must be inspected by a quali-
fied  electrician  before  the  dust  collector  is  con-
nected to the power source. if, at any time during 
this  procedure  you  need  help,  call  grizzly  tech 
support at (570) 546-9663.
440v Conversion
power Supply Circuit Requirements
you Must connect your machine to a grounded 
circuit that is rated for the amperage given below. 
never replace a circuit breaker on an existing cir-
cuit with one of higher amperage without consult-
ing  a  qualified  electrician  to  ensure  compliance 
with wiring codes. 
if you are unsure about the 
wiring codes in your area or you plan to con-
nect your machine to a shared circuit, consult 
a qualified electrician.