g0671/g0672/g0673 dust Collector
Determining Main Line Duct Size
the general rule of thumb for a main line duct is 
that the velocity of the airflow must not fall below 
3500 FpM.
use the inlet size of the dust collector as a starting 
point for the main line. neck the main line down 
1"  for  every  10'  of  length.  this  will  usually  keep 
the air velocity above 3500 FpM and, depending 
on  your  system,  will  allow  you  to  keep  multiple 
branches open at one time.
For  the  Model  g0671/g0672/g0673  this  is  10". 
Mark your drawing, as in 
figure 33.
figure 33. Main line size labeled on sketch.
(.*
(.*
+&)
,.%
(.*
''%
.-
9“
10“
Determining branch Line Duct Size
the general rule of thumb for a branch line duct is 
that the velocity of the airflow must not fall below 
4000 FpM.
For  small/medium  sized  shops,  using  the  dust 
port size from the machine as the branch line duct 
size will achieve the correct velocity in most appli-
cations. however, if the dust port on the machine 
is  smaller  than  4",  make  the  branch  line  4"  and 
reduce the line right before the dust port.
Note: Systems with powerful dust collectors work 
better  if  multiple  blast  gates  are  left  open.  This 
also  allows  you  to  run  two  machines  at  once. 
Experiment  with  different  combinations  of  blast 
gates open/closed to find the best results for your 
system.
Write  your  determined  branch  line  sizes  on  your 
drawing, as shown in 
figure 34.
figure 34. Branch line sizes labeled on sketch.
(.*
(.*
+&)
,.%
(.*
''%
.-
9“ 
10“
6“ 
4“ 
4“ 
4“ 
4“ 
4“ 
5“ 
Multiple Dust ports
if your machine has multiple dust ports, add the 
total  CFM  given  for  each  dust  port  size  from 
figure 30. refer to figure 35 and find the CFM 
that is closest to your total to determine the cor-
rect branch size. split the branch line just before 
the dust ports with matching duct sizes.
Two Machines on Same branch Line
if both machines will be running at the same time, 
add  the  total  CFM  given  for  each  dust  port  size 
from 
figure 30.
if both the machines will never be run at the same 
time,  reference  the  machine  with  biggest  dust 
port  to 
figure  35  and  add  blast  gates  after  the 
y-branch to open/close the line to each machine.
Total CfM
branch Line Size
<500
4"
600
5"
700
5"
800
6"
1000
6"
1200
7"
1400
8"
1600
8"
figure 35. Branch line sizing chart by total CFM 
(for use when multiple machines share line).