Pelco C1520M-B User Manual

Page of 61
Pelco Manual C573M-D (11/03)
43
A
B
C
D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
120VAC
COM1 COM2
UNIT ID
PGM
MON
OUTPUT
INPUT
5.25
(13.21)
17.40 (44.20)
18.97 (48.18)
5.25
(13.21)
12.90 (32.77)
NOTE:  VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES
Figure 36.  CM9760-MDA Dimension Drawing
General
Construction:
Aluminum
Dimensions:
See Figure 36
Mounting:
19-in. (48.26 cm) EIA standard rack mount (3 RUs)
Operating Temperature: 14° to 122°F (-10° to 50°C)
Humidity:
90% non-condensing
Memory Backup:
Lithium battery
Ratings
NEMA 1
(Design and product specifications subject to change without notice.)
REAR
VIEW
SIDE
VIEW