DOUBLE INSULATION
Double insulation is a concept in safety in electric power 
tools,  which  eliminates  the  need  for  the  usual  three-wire 
grounded power cord. All exposed metal parts are isolated 
from the internal metal motor components with protecting 
insulation.  Double  insulated  tools  do  not  need  to  be 
grounded.
WARNING:
The double insulated system is intended to protect 
the user from shock resulting from a break in the 
tool’s  internal  wiring.  Observe  all  normal  safety 
precautions to avoid electrical shock.
NOTE: Servicing of a tool with double insulation requires 
extreme  care  and  knowledge  of  the  system  and  should 
be  performed  only  by  a  qualified  service  technician.  For 
service,  we  suggest  you  return  the  tool  to  your  nearest 
authorized  service  center  for  repair.  Always  use  original 
factory replacement parts when servicing.
ELECTRICAL CONNECTION
This tool has a precision-built electric motor. It should be 
connected to a 
power supply that is 120 volts, 60 Hz, AC 
only (normal household current). Do not operate this tool 
on direct current (DC). A substantial voltage drop will cause 
a loss of power and the motor will overheat. If your tool does 
not operate when plugged into an outlet, double-check the 
power supply.
EXTENSION CORDS
When using a power tool at a considerable distance from 
a power source, be sure to use an extension cord that has 
the  capacity  to  handle  the  current  the  tool  will  draw.  An 
undersized cord will cause a drop in line voltage, resulting in 
overheating and loss of power. Use the chart to determine 
the minimum wire size required in an extension cord. Only 
round jacketed cords listed by Underwriter’s Laboratories 
(UL) should be used.
When  working  outdoors  with  a  tool,  use  an  extension 
cord that is designed for outside use. This type of cord is 
designated with “WA” on the cord’s jacket.
Before  using  any  extension  cord,  inspect  it  for  loose  or 
exposed wires and cut or worn insulation.
**Ampere rating  (on tool faceplate)
 
0-2.0 
2.1-3.4 
3.5-5.0 
5.1-7.0  7.1-12.0   12.1-16.0
Cord Length   
Wire Size (A.W.G.)
    25'             16          16         16         16         14        14
    50'             16          16         16         14         14        12
  100'             16          16         14         12         10        —
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge
WARNING:
Keep the extension cord clear of the working area. 
Position the cord so that it will not get caught on 
lumber, tools or other obstructions while you are 
working with a power tool. Failure to do so can 
result in serious personal injury.
WARNING:
Check  extension  cords  before  each  use.  If 
damaged replace immediately. Never use tool with 
a damaged cord since touching the damaged area 
could cause electrical shock resulting in serious 
injury.
ELECTRICAL