Emulex 3.4 User Manual

Page of 154
The HBAnyware Utility User Manual
Page 92
Driver for VMware ESX Configuration Parameters
All HBA-specific parameters have an lpfcX_ prefix (where X is the driver instance number); e.g., setting 
lpfc0_lun_queue_depth= 20 makes 20 the default number of maximum commands which can be sent to 
a single logical unit (disk) for lpfc instance 0.
Dynamic parameters do not require the driver to be unloaded and reloaded for changes to take effect.
lpfc_use_adisc
0
0=Off
1=On
Sends ADISC instead of 
PLOGI for device discovery or RSCN.
Table 11: Driver for VMware ESX Configuration Parameters 
Variable
Default
Min
Max
Dynamic
Comments
lpfc_hba_queue_depth  
8192
0
8192
Yes
Maximum number of FCP 
commands that can queue to an 
Emulex HBA. 
lpfc_initiator_login   
0
0
1
Yes
Enables logins to other virtual 
initiators.
lpfc_ack0
0
0=Off
1=On
No
Use ACK0 for class 2.
lpfc_automap
1
0=Off
1=On
No
Automatically assign SCSI IDs to 
FCP targets detected.
lpfc_check_cond_err
0
0=Off
1=On
Yes
Treat certain FCP check conditions 
as FCP RSP errors.
lpfc_cr_count
1
1
255
No
This parameter determines the 
values for I/O coalescing for 
cr_delay (msec) or cr_count 
outstanding commands. 
lpfc_cr_delay
0
0
63
No
This parameter determines the 
values for I/O coalescing for 
cr_delay (msec) or cr_count 
outstanding commands.
lpfc_delay_rsp_err
0
0=Off
1=On
Yes
Treat FCP RSP errors like no-
device-delay.
lpfc_discovery_threads
1
30
64
No
Specifies the maximum number of 
ELS commands that can be 
outstanding for a discovery.
lpfc_dqfull_throttle_up_inc
1
0
128
Yes
Amount to increment LUN queue 
depth each time.
lpfc_dqfull_throttle_up_tim
e
1
0
30
Yes
Time interval, in seconds, to 
increment LUN queue depth.
lpfc_extra_io_tmo
0
0
255
Yes
Extra FCP cmd timeout when 
connected to a fabric (in seconds).
Table 10: lpfc Dynamic Parameters (Do not require a driver reload to change) (Continued)
Variable
Default
Min
Max
Comments