Improper connection of the equipment-grounding 
wire  can  result  in  a  risk  of  electric  shock.  The 
wire with green insulation (with or without yellow 
stripes) is the equipment-grounding wire. If repair 
or replacement of the power cord or plug is nec-
essary, do not connect the equipment-grounding 
wire to a live (current carrying) terminal.
 
Check with a qualified electrician or service per-
sonnel if you do not understand these grounding 
requirements, or if you are in doubt about whether 
the  tool  is  properly  grounded.  If  you  ever  notice 
that a cord or plug is damaged or worn, discon-
nect it from power, and immediately replace it with 
a new one.
Grounding Requirements
This  machine  MUST  be  grounded.  In  the  event 
of certain malfunctions or breakdowns, grounding 
reduces the risk of electric shock by providing a 
path of least resistance for electric current.
figure 2. typical 5-15 plug and receptacle.
Grounding Prong
Neutral Hot
5-15 PLUG
GROUNDED
5-15 RECEPTACLE
figure 3. typical 6-15 plug and receptacle.
Grounding Prong
Current Carrying Prongs
6-15 PLUG
GROUNDED
6-15 RECEPTACLE
Serious  injury  could  occur  if  you  connect 
the machine to power before completing the 
setup  process.  DO  NOT  connect  to  power 
until instructed later in this manual.
For  110V  operation:  This  machine  is  equipped 
with a power cord that has an equipment-ground-
ing wire and a grounding plug (see following fig-
ure). The plug must only be inserted into a match-
ing  receptacle  (outlet)  that  is  properly  installed 
and grounded in accordance with all local codes 
and ordinances.
For  220V  operation:  The  plug  specified  under 
“Circuit  Requirements  for  220V”  on  the  previous 
page has a grounding prong that must be attached 
to the equipment-grounding wire on the included 
power cord. The plug must only be inserted into 
a  matching  receptacle  (see  following  figure)  that 
is properly installed and grounded in accordance 
with all local codes and ordinances.
SHOCK HAZARD!
Two-prong outlets do not meet the grounding 
requirements for this machine. Do not modify 
or use an adapter on the plug provided—if 
it  will  not  fit  the  outlet,  have  a  qualified 
electrician  install  the  proper  outlet  with  a 
verified ground.