21. OPERATE COMPRESSOR AT THE RATED VOLTAGE. 
Operate the compressor at voltages specified on their nameplates. 
If using the compressor at a higher voltage than the rated voltage, it 
will result in abnormally fast motor revolution and may damage the 
unit and burn out the motor. 
 
22. NEVER USE A COMPRESSOR WHICH IS DEFECTIVE OR 
OPERATING ABNORMALLY. 
If the compressor appears to be operating unusually, making strange 
noises or vibration, or otherwise appears defective, stop using it 
immediately and arrange for repairs by a Hitachi authorized service 
center. 
 
23. DO NOT WIPE PLASTIC PARTS WITH SOLVENT. 
Solvents such as gasoline thinner, benzene, carbon tetrachloride, 
and alcohol may damage and crack plastic parts. Do not wipe them 
with such solvents. Wipe plastic parts with a soft cloth lightly 
dampened with soapy water and dry thoroughly. 
 
24. USE ONLY GENUINE HITACHI REPLACEMENT PARTS. 
Replacement parts not manufactured by Hitachi may void your 
warranty and can lead to malfunction and resulting injuries. Genuine 
Hitachi parts are available from your dealer. 
 
25. DO NOT MODIFY THE COMPRESSOR. 
Do not modify the compressor. Do not operate at pressure or speed 
in excess of manufacturer’s recommendations. Always contact the 
Hitachi authorized service center any repairs. Unauthorized 
modification may not only impair the compressor performance but 
may also result in accident or injury to repair personnel who do not 
have the required knowledge and technical expertise to perform the 
repair operations correctly. 
 
26. PUSH THE KNOB OF PRESSURE SWITCH TO OFF WHEN 
THE COMPRESSOR IS NOT USED. 
When the compressor is not used, push the knob of the pressure 
switch OFF, disconnect it from the power source and open the drain 
cock to discharge the compressed air from the air tank. 
 
27. NEVER TOUCH HOT SURFACE 
To reduce the risk of burns, do not touch tubes, heads, cylinder and 
motors.  
 
28. DO NOT DIRECT AIR STREAM AT BODY. 
Risk of injury, do not direct air stream at persons or animals. 
 
29. DRAIN TANK 
Risk of bursting. Water will condense in the air tank. If not drained, 
water will corrode and weaken the air tank causing a risk of air tank 
rupture. Drain tank daily or after 4 hours of use. To drain tank open 
valve slowly and tilt compressor to empty accumulated water. 
 
30. DO NOT STOP COMPRESSOR BY PULLING OUT THE 
PLUG. 
This could result in damage to the unit. 
Use the “ON/OFF” knob of pressure switch. 
 
31. MAKE SURE THE COMPRESSOR OUTLET PRESSURE IS 
SET LOWER THAN THE MAXIMUM OPERATING PRESSURE OF 
THE TOOL. 
Too much air pressure causes a hazardous risk of bursting. Check 
the manufacturer’s maximum pressure rating for air tools and 
accessories. The regulator outlet pressure must never exceed the 
maximum pressure rating. 
 
32. THE SAFETY VALVE MUST WORK PROPERLY. 
Risk of bursting. Before starting the compressor pull the ring on the 
safety valve to make sure the valve moves freely. If the safety valve 
does not work properly, over-pressurization may occur, causing air 
tank rupture or an explosion.  
 
33. USE OF THIS PRODUCT WILL EXPOSE YOU TO 
CHEMICALS KNOWN TO THE STATE OF CALIFORNIA. 
Some dust created by this product contains chemicals known to 
State of California to cause cancer, birth defects or other 
reproductive harm. Some examples of these chemicals are: 
- compounds in fertilizers 
- compounds in insecticides, herbicides and pesticides 
- arsenic and chromium from chemically treated lumber 
To reduce your exposure to these chemicals, wear approved safety 
equipment such as dust masks that are specially designed to filter 
out microscopic particles. Use of this product will expose you to 
chemicals known to the State of California to cause cancer, birth 
defects and other reproductive harm. Avoid inhaling vapors and dust, 
and wash hands after using. This product contains chemicals, 
including lead, known to the State of California to cause cancer, and 
birth defects or other reproductive harm. Wash hands after handling. 
 
.
 
 
 
 
REPLACEMENT PARTS 
 
When servicing use only identical replacement parts. 
Repairs should be conducted only by a Hitachi authorized service center.