Atlas Air Compressor User Manual
Instruction book
2920 1521 00
56
8.11.2 To activate/deactivate the timer
1. Starting from the Main screen (see section 8.1.2):
-
press the key "Menu" (F1)
- press
the
↓ key until the option "Modify parameters" is followed by a horizontal arrow
-
press the tabulator key (5) to activate the menu
2. Use
the
↓ key to scroll until the option "Clock function" is followed by a horizontal arrow. Press the
tabulator key (5), following screen appears:
Clock Function
Not
activated
→
Menu Modify Delete
F1 F2 F3
3. Press the key "Modify", "Not activated" starts blinking.
4. Press
the
↓ key, "Not activated" changes into "Activated".
5. Press the key "Program".
Important:
1. It is necessary to program the start/stop/pressure band commands in successive order timewise,
Important:
1. It is necessary to program the start/stop/pressure band commands in successive order timewise,
e.g.:
07.30 start
07.30 pressure band 1
08.30 pressure band 2
17.00 stop
etc.
07.30 start
07.30 pressure band 1
08.30 pressure band 2
17.00 stop
etc.
2. Make sure that the clock function is activated (indicated as "Activated"). If not, the programmed
start/stop commands will not be executed.
8.11.3 To modify a command
Suppose the command to stop the compressor on Saturday 18:00 is to be modified: stopping at 17
o'clock instead of 18 o'clock:
1. Starting from the Main screen (see section 8.1.2):
-
press the key "Menu" (F1)
- press
the
↓ key until the option "Modify parameters" is followed by a horizontal arrow
-
press the tabulator key (5) to activate the menu