Grizzly G0469 User Manual

Page of 32
Model G0466/G0469 Air Compressors
-
7
-
This  machine  must  have  a  ground 
prong in the plug to help ensure that it 
is grounded. DO NOT remove ground 
prong  from  plug  to  fit  into  a  two-
pronged  outlet!  If  the  plug  will  not 
fit  the  outlet,  have  the  proper  outlet 
installed by a qualified electrician.
SECTION 2: CIRCUIT 
REQUIREMENTS
Figure 1. Typical type 5-15 plug and 
receptacle.
Serious personal injury could occur 
if  you  connect  the  machine  to  the 
power source before you have com-
pleted  the  set  up  process.  DO  NOT 
connect  the  machine  to  the  power 
source until instructed to do so.
110V Operation
Amperage Draw
The  motors  on  the  air  compressors  will 
draw the following amps:
G0466 Motor Draw ...................... 8 Amps
G0469 Motor Draw .....................14 Amps
Circuit Requirements
Only  connect  your  machine  to  a  cir-
cuit  that  meets  the  requirements  below. 
Always  check  to  see  if  the  wires  and 
circuit breaker in your circuit are capable 
of handling the amperage draw from your 
machine,  as  well  as  any  other  machines 
that  could  be  operating  on  the  same  cir-
cuit. If you are unsure, consult a qualified 
electrician. 
Model G0466
Minimum Circuit Requirement ..... 15 Amp
Model G0469
Minimum Circuit Requirement ..... 20 Amp
Plug/Receptacle Type
Plug Type ..............NEMA 5-15 (
Figure 1)