table tilt Calibration
When the table is perpendicular to the sanding
disc, the scale should read 0˚. if not, follow this
procedure.
disc, the scale should read 0˚. if not, follow this
procedure.
tools needed:
machinist's square ............................................. 1
phillips head screwdriver ................................... 1
machinist's square ............................................. 1
phillips head screwdriver ................................... 1
to calibrate the table tilt:
1. disCoNNeCt mAChiNe From poWer!
2. Using a try square or machinist’s square, set
one edge on the table surface and the other
against the face of the disc, as shown in
against the face of the disc, as shown in
figure 26.
note: Although this can be done with the
sandpaper installed, it is more precise with-
out it.
sandpaper installed, it is more precise with-
out it.
3. loosen the lock handles and adjust the table
angle until it is perfectly perpendicular to the
disc, then tighten the lock handles while hold-
ing the table in place.
disc, then tighten the lock handles while hold-
ing the table in place.
4. loosen the degree scale pointer, index the
pointer on 0˚, then retighten the screw.
5. recheck the scale accuracy with the square.
figure 26. squaring the table.