Tektronix TDS420A User Manual

Page of 433
Command Descriptions
2–294
TDS Family Oscilloscope Programmer Manual
MOREThan
LESSThan
FALSe
<Space>
?
TRUe
:
MAIn
TRIGger
LOGIc
:
:
PATtern
WHEn
:
TRUe specifies the trigger to occur when the pattern becomes true.
FALSe specifies the trigger to occur when the pattern becomes false.
LESSThan specifies trigger to occur if the specific pattern is true less than the
LESSLimit. (see Figure 2–6 and 
TRIGger:MAIn:LOGic:PATĆ
tern:WHEn:LESSLimit) Trigger is evaluated at the true-false transition.
MOREThan specifies trigger to occur if the specific pattern is true longer than the
more limit. (see Figure 2–6 and 
TRIGger:MAIn:LOGic:PATtern:WHEn:MORELiĆ
mit) Trigger is evaluated at the true-false transition.
Specified Pattern
Result
MORELimit
LESSLimit
t
o
Figure 2–6: LESSThan and MOREThan Arguments
TRIGger:MAIn:LOGIc:PATtern:WHEn:LESSLimit
Not on TDS 400A
Sets or queries the maximum time the selected pattern may be true and still
generate a main logic pattern trigger.
Trigger
TRIGger:MAIn:LOGIc:PATtern:WHEn:LESSLimit <NR3>
TRIGger:MAIn: LOGIc: PATtern: WHEn: LESSLimit?
Arguments
Group
Syntax